ServerNet Nomadic Disk User's Guide
Switch Modules
ServerNet Nomadic Disk User’s Guide—425485-001
4-4
SCC Key Switch
SCC Key Switch
The key switch on the SCC allows you to access switch cards either locally or remotely 
by turning the key switch from LOCAL (L) to REMOTE (R).
•
When the key switch is in the LOCAL position: 
•
You can change the position of the switches by manually moving the toggle 
switch on the switch cards. 
•
You can check the status of the switch module using SWCI status commands.
SWCI action commands, such as the SWITCH command, have no effect on this 
switch module, and Nomadic Disk Manager commands that rely on SWCI 
action commands also have no effect. Turning the key switch to the LOCAL 
position disables control from switch-controller software. 
•
When the key switch is in the REMOTE position: 
•
You can change the switches on each switch card in this switch module using 
switch-controller software, such as SWCI or the Nomadic Disk Manager.
•
You cannot change the switches by manually moving the toggle switch on each 
switch card.  Turning the key switch to the REMOTE position disables the 
toggle switches on the switch cards. The toggle switches can be moved, but they 
have no effect.
SCC Temperature Sensors
The SCC contains two temperature sensors. .  
Sensor Monitors Temperature of 
1 Switch module
2 Circuit board in the SCC