ServerNet Nomadic Disk User's Guide
Switchovers
ServerNet Nomadic Disk User’s Guide—425485-001
5-4
Moving the Fiber Optic Switches to the Opposite
Position
Moving the Fiber Optic Switches to the Opposite 
Position
A switch card determines the position of the fiber-optic switch: straight or crossed. To 
move the fiber-optic switches to another position,  do one of the following:
•
If you are using Nomadic Disk Manager, the GIVE command performs the 
switching. 
•
If you are not using Nomadic Disk Manager:
•
Issue commands from the Switch Command Interface (SWCI) to each switch. 
See Section 6, Switch Command Interface (SWCI). The SWCI commands affect 
the switch card only if the key switch on the switch controller card is set to the 
REMOTE position.
•
Physically move the toggle switches. The toggle switches affect the switch card 
only if the key switch on the switch controller card is set to the LOCAL 
position. 
Example 5-2. NDCONFIG on \BCK 
SET PATH P $ MOD1.#A 1 CROSSED 
SET PATH B $ MOD1.#A 2 CROSSED 
SET PATH M $TRM1.#A 1 STRAIGHT 
SET PATH MB $ TRM1.#A 2 STRAIGHT 
SET VOL $DATA01 
SET VOL $DATA02 
SET VOL $DATA03 
SET VOL $DATA04 
SET VOL $DATA05 
SET VOL $DATA06 
SET VOL $DATA07 
SET VOL $DATA08 
ADD SEGMENT SEGMENT-1, DATA