Error Messages
ServerNet/FX Adapter Configuration and Management Manual—426872-002
B-7
FOX SCF Command Error Messages
FOX E00109
Cause. The value specified for the processor is out of range or the processor is
nonexistent.
Effect. The START PATH command was not executed.
Recovery. Reissue the START PATH command with valid processor values.
FOX E00110
Cause. The name specified for the path is invalid. Valid values are XL, XR, YL, YR, or
ALL.
Effect. The START PATH command was not executed.
Recovery. Reissue the START PATH command with a valid path name.
FOX E00111
Cause. The local system name cannot be specified as the remote system.
Effect. The START PATH command was not executed.
Recovery. Reissue the START PATH command with a valid remote system name.
FOX E00112
Cause. The cause could be any of the following:
•
The Expand-over-FOX line-handler process for the cluster in the local system is
not started.
•
The Expand-over-FOX line-handler process for the local system in the remote
cluster is not started.
•
Both LBUs ($ZZFOX.#X or $ZZFOX.#Y) associated with the ServerNet/FX
adapters are in the STOPPED state.
Effect. The START PATH command was not executed.
Recovery. Reissue the START PATH command after troubleshooting the cause of the
problem.
CPU valid values 0 - 15.
Path name specified is invalid.
Local system name cannot be specified in this field.
Path to the cluster specified is down.