ServerNet/FX Adapter Configuration and Management Manual

Table Of Contents
ServerNet/FX Adapter Subsystem SCF Commands
ServerNet/FX Adapter Configuration and Management Manual426872-002
4-14
ALTER Command
PROGRAM
The PROGRAM attribute is the name of the file (file-spec) containing the
downloadable operational microcode for the ServerNet/FX adapter specified by
the LBU.
MODULE
The MODULE attribute is the name of the object module (module-name) in
the microcode file file-spec.
SAMPLEINT
The SAMPLEINT attribute specifies the interval after which the FOX monitor
process ($ZZFOX) resets all statistical counters to zero for the specified
ServerNet/FX adapter. time has the form hh:mm:ss.lll, where hh is hours,
mm is minutes, ss is seconds, and lll is milliseconds. If you specify only one
or two digits, they are interpreted as seconds. If you specify two sets of digits
separated by a colon, they are interpreted as minutes and seconds.
CLUSTERNUM
The CLUSTERNUM attribute specifies the unique cluster number
(cluster-number) of the server. If the cluster number is set to 0, the
specified ServerNet/FX adapter cannot be started until the cluster number is
changed to a valid value.
Default ServerNet/FX adapter: $SYSTEM.SYSTEM.M6740
ServerNet/FX 2 adapter: $SYSTEM.SYSTEM.M6742
Units Not applicable
Range Not applicable
Caution. Never put a copy of M6740 or M6742 in the $SYSTEM.SYSTEM subvolume.
Default STANDARD
Units Not applicable
Range Not applicable
Default 1:00:00.000
Units 0.01 seconds
Range 30 seconds through 8 hours
Default 0
Units Not applicable
Range 1 through 14