SNAX Connection Manager (SNAX/CM) Manual

16: ZSXC-EVT-DISCONNECT-FAILED
SNAX/CM Event Messages
097842 Tandem Computers Incorporated A–19
ZSXC-TKN-STATUS
reports the status of the line:
1 Not Available
2 Disconnected
3 Disconnecting
4 Allowing
5 Calling
6 Connected
ZSXC-TKN-RC
is a SNAX/CM return code. Refer to Appendix B, “SNAX/CM Messages and
Codes,” in this manual for more information.
ZSXC-TKN-FE
is a file-system error that indicates why the event occurred. Refer to the Guardian
Procedure Errors and Messages Manual for information about the error.
Conditional Tokens
ZCOM-TKN-SUBJ-SU
is an optional token that contains the name of the subdevice for which this event
occurred.
Cause. This message occurs when a SNAX/CM DISCONNECT command is issued by
the user and the line has not been started or is not a line configured for SNAX/CM
operations using the CONNECTAPPL system generation line attribute. This message
also occurs when a SNAX/CM DISCONNECT operation is started after receiving a
CALL REJECT message from the call validate or XID validate server process. Refer to
the status message, as well as any return code and file-system error message, to
determine the cause.
Effect. A SNAX/CM disconnect operation failed because a line is unavailable.
Recovery. Verify that the SNAX/XF line and PU were started, as well as the X25AM or
Token-Ring line and subdevice. Also check that the APPL object was added using the
SCF ADD APPL command and that it is the correct type. Retry the failing operation.