SNAX Connection Manager (SNAX/CM) Manual
Text Messages
SNAX/CM Messages
097842 Tandem Computers Incorporated B–17
time-date
 LOG (#17):
LINE 
line-name
 [, PORT 
port-name
],
MONITOR STATUS, STATUS: { DISCONNECTED | UNAVAILABLE, }
RC = 
rc-code
, FE = 
fe-error
Cause. Another process is using this line.
Effect. This line is disconnected.
Recovery. Check the return code and file-system error number to determine the reason
for the command not being accepted.
time-date
 LOG (#18):
PORT STATUS for LINE 
line-name, 
PORT 
port-name
SAMPLE TIME : 
timestamp
LINE TYPE: { SWITCHED FLOATING | PERMANENTLY SUBORDINATE }
PUNAME: { 
pu-name
 | N/A }
STATUS: 
 port-status
ENABLED: { YES | NO }
CALLSTRING: 
callstring
XIDSTRING: 
xidstring
ALIASLU: 
alias_lu_name
ALIASLUCNT: 
alias-lu-count
Cause. The STATUS PORT command completes successfully.
Effect. SNAX/CM logs this message; 
port-status 
can be one of the following :
Not Available
Disconnected
Disconnecting
Allowing
Calling
Connected
Recovery. Informational message only; no corrective action is needed.