SNAX Connection Manager (SNAX/CM) Manual

STATUS LINE, PU Command
SNAX/CM Commands
097842 Tandem Computers Incorporated 3–31
STATUS LINE, PU Command
The SNAX/CM STATUS LINE, PU command details the connection status for a PU
and is requested by using the following syntax:
S[TATUS] LINE
line-name
,
PU
pu-name
return : (OUTFILE)
{ PU STATUS FOR PUNAME:
pu-name
SAMPLE TIME:
timestamp
PU TYPE: { SWITCHED FLOATING | PERMANENTLY SUBORDINATE }
LINE: {
line-name
| N/A }
PORT
port-name
| N/A }
STATUS:
pu-status
CALLSTRING: {
callstring
| N/A }
XIDSTRING: {
xidstring
| N/A }
ALIASLU:
alias-lu-name
ALIASLUCNT:
alias-lu-count
| ERROR MESSAGES }
return : ($RECEIVE)
STRUCT PU^Status^Reply;
BEGIN
STRING base[ 0:-1 ];
INT Return^code;
INT Ferror;
INT Status; -- 1 = Unavailable
-- 2 = Disconnected
-- 3 = Disconnecting
-- 4 = Allowing
-- 5 = Calling
-- 6 = Connected
INT PU^type; -- 0 = Permanently Subordinate
-- 1 = Switched Floating
STRUCT PUname( VARSTRING );
STRUCT linename( VARSTRING );
STRUCT portname( VARSTRING );
STRUCT callstring( VARSTRING );
STRUCT xidstring( VARSTRING );
STRUCT alias^lu( VARSTRING );
INT alias^lu^count;
STRING data[ 0:-1 ]; -- variable data for VARSTRINGs
END