SNAX Connection Manager (SNAX/CM) Manual
STATUS PU Command
SNAX/CM Commands
3–34 097842 Tandem Computers Incorporated
STATUS PU Command
The SNAX/CM STATUS PU command locates a switched floating PU, either in the
pool of floating PUs or after the PU is assigned to a line. The STATUS PU command is
requested by specifying the PU name for switched floating PUs.
The syntax for the SNAX/CM STATUS PU command is as follows:
S[TATUS]
PU 
pu-name
return : (OUTFILE)
{ PU STATUS FOR PUNAME: 
pu-name
 SAMPLE TIME: 
timestamp
 PU TYPE: SWITCHED FLOATING
 LINE: {
line-name 
| $SSCP }
 PORT 
port-name
 | N/A }
 STATUS: 
pu-status
 CALLSTRING: { 
callstring 
| N/A }
 XIDSTRING: { 
xidstring 
| N/A }
 ALIASLU: 
alias-lu-name
 ALIASLUCNT: 
alias-lu-count
| ERROR MESSAGES }
return : ($RECEIVE)
STRUCT PU^Status^Reply;
 BEGIN
 STRING base[ 0:-1 ];
 INT Return^code;
 INT Ferror;
 INT Status; -- 1 = Unavailable
 -- 2 = Disconnected
 -- 3 = Disconnecting
 -- 4 = Allowing
 -- 5 = Calling
 -- 6 = Connected
 INT PU^type; -- 1 = Switched Floating
 STRUCT PUname( VARSTRING );
 STRUCT linename( VARSTRING );
 STRUCT portname( VARSTRING );
 STRUCT callstring( VARSTRING );
 STRUCT xidstring( VARSTRING );
 STRUCT alias^lu( VARSTRING );
 INT alias^lu^count;
 STRING data[ 0:-1 ]; -- variable data for VARSTRINGs
 END