SNAX Creator-2 Configuration and Control Manual

INFO Command
SCF Commands for SNAX Creator-2
4–20 117143 SNAX Creator-2 Configuration and Control Manual
subtype
is an object type subordinate to the object named in the command, as described in
Section 3, “Objects for SNAX Creator-2.”
Considerations
For SNAX Creator-2, the DETAIL option can be specified for all object types.
Asterisks (*) in the returned displays indicate information that can be altered for
the object with the ALTER command.
The INFO commands for the SNAX Creator-2 subsystem reflect only what was
entered in the ADD or ALTER command. The INFO commands do not reflect any
default values or evaluated values.
If a value string in an INFO command is too long to fit in the display space, plus
signs (++) are displayed, along with a message indicating that truncation has
occurred. When this happens, use the INFO command with the DETAIL
parameter to view the entire value string.
The INFO CONNECTION command displays only connection names matching
object-name
. If you specify the connection name in the command, no new
information is displayed. However, you can use wild-card characters when
specifying
object-name
, in which case all connection object names that match
the description are displayed.