SNAX/APC Application Programming Manual
Application Prototype Simulator
SNAX/APC Application Programming Manual—138786
4-56
MC-RECEIVE-AND-WAIT (F5)
MC-RECEIVE-AND-WAIT (F5)
The MC-RECEIVE-AND-WAIT verb receives data or control information from the
partner TP. If a TP issues the MC-RECEIVE-AND-WAIT verb while in the Send state,
SNAX/APC transmits any data in the local LU’s send buffer and then places the
conversation in the Receive state. The MC-RECEIVE-AND-WAIT verb completes
when the local TP receives data or control information from the partner TP.
Request Fields
Data Length (Max 480)
specifies the maximum amount of data that the local TP (APS) can receive in one
reply. The maximum length you can specify is 480 bytes.
Reply Fields
IPC Return Code
displays the value of HEADER-RETURN-CODE returned in the IPC header reply.
IPC Return Code Detail
displays the value of HEADER-RETURN-CODE-DETAIL returned in the IPC
header reply.
UOWs In
displays the number of UOWs in this IPC message (always 1 for APS).
SNAX/APC Application Prototype Simulator (APS) System (T9096D30 22JUN95 F15)
Request: MC_Receive_And_Wait Resource ID: 0 5 0 0707D
Data Length (Max 480): 80
Reply: MC_Receive_And_Wait
IPC Return Code: 0 IPC Ok
IPC Return Code Detail: 0 IPC Ok
UOWs In: 0001 UOWs Out: 0001
Header Return Code: 0 RC Ok
Request To Send Ind: N Data Type: Data-Complete
Data Length: 80
User Data: ralph
Request Completed
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15
F16
TPR MAl MDal TPE MR&W MRTS MSD MSE MCnf MCfd MGA MSnd Prnt Hex Rcov
Exit
ActS Dact MPrc MRcI MFls Gtyp GTP A(T) E(T)
Exit