SNAX/APC Application Programming Manual
Application Prototype Simulator
SNAX/APC Application Programming Manual—138786
4-56
MC-RECEIVE-AND-WAIT (F5)
MC-RECEIVE-AND-WAIT (F5)
The MC-RECEIVE-AND-WAIT verb receives data or control information from the 
partner TP. If a TP issues the MC-RECEIVE-AND-WAIT verb while in the Send state, 
SNAX/APC transmits any data in the local LU’s send buffer and then places the 
conversation in the Receive state.  The MC-RECEIVE-AND-WAIT verb completes 
when the local TP receives data or control information from the partner TP.
Request Fields
Data Length (Max 480)
specifies the maximum amount of data that the local TP (APS) can receive in one 
reply. The maximum length you can specify is 480 bytes.
Reply Fields
IPC Return Code
displays the value of HEADER-RETURN-CODE returned in the IPC header reply.
IPC Return Code Detail
displays the value of HEADER-RETURN-CODE-DETAIL returned in the IPC 
header reply.
UOWs In
displays the number of UOWs in this IPC message (always 1 for APS).
SNAX/APC Application Prototype Simulator (APS) System (T9096D30 22JUN95 F15)
Request: MC_Receive_And_Wait  Resource ID: 0 5 0 0707D
Data Length (Max 480):  80      
Reply: MC_Receive_And_Wait
IPC Return Code:  0 IPC Ok
IPC Return Code Detail: 0 IPC Ok
UOWs In:   0001 UOWs Out: 0001
Header Return Code:  0 RC Ok
Request To Send Ind:  N Data Type: Data-Complete
Data Length:   80
User Data: ralph
Request Completed
F1 F2 F3  F4 F5 F6  F7 F8 F9  F10 F11 F12  F13 F14 F15 
F16
TPR MAl MDal TPE MR&W MRTS MSD MSE MCnf MCfd MGA MSnd Prnt Hex Rcov 
Exit
ActS Dact  MPrc MRcI MFls Gtyp GTP    A(T) E(T) 
Exit