SNAX/APC Application Programming Manual
Interprocess Communications and Units of Work
SNAX/APC Application Programming Manual—138786
2-10
IPC Return Code Details
3SEVICE-
DENIED
(Cont.)
417 SYNC-LEVEL-
NOT-SUPPTD-
BY-LU
Returned if the ADD LU specified
LOCAL-LU-SYNC2-SUPPORT
NONE and the TP^READY specifies
SYNC-SUPPORT Y.
4 INVALID-
UOW-
HEADER
302 INVALID-
INDICATOR
A request UOW contained an invalid
indicator (such as a value other than Y
or N in the TP-READY local attach
indicator field).
303 INVALID-
TPNAME
A request specified a local TP name
not defined in the configuration
database, or an unauthorized TP issued
a general TP-READY request.
304 INVALID-
LUNAME
The LU specified in the request is not
defined in the configuration database.
305 INVALID-
SEND-
LENGTH
The total length of the IPC message
exceeded the value of the
MAXAPPLIOSIZE PARAM.
306 INVALID-
TYPE
A request type indicator is in error.
This detail field can be returned for
either the (MC)DEALLOCATE or
(MC)SEND-ERROR request UOWs.
307 INVALID-
APC-VERB
SNAX/APC detected an invalid verb
code.
309 INVALID-
RCVD-
LENGTH
A MAX-DATA-LENGTH was
specified in a RECEIVE-AND-WAIT
or a RECEIVE-IMMEDIATE verb that
would cause the complete reply
(including the IPC header, the reply
header, and any other UOWs in the
IPC) to exceed the value specified in
MAXAPPLIOSIZE when SNAX/APC
was started.
326 INVALID-
SESSION-ID
Returned to DEACTIVATE^SESSION
if Session ID exceeds
MAXSESSIONS.
327 SYNCPT-
NOT-
ENABLED
SNAX/APC is not licensed for sync
point support
9SNAX-FILE-
ERROR
file-system error number HEADER-RETURN-CODE-DETAIL
contains an operating system error
number.
Table 2-2. IPC Return Code Details (page 3 of 3)
HEADER-RETURN-
CODE
HEADER-RETURN-
CODE-DETAIL
Value Label Value Label Meaning