SNAX/APC Configuration and Management Manual

Trace Analysis Program
SNAX/APC Configuration and Management Manual138787
5-24
Error Version (Trace Format)
The RH contains all zeros. The BIN/BOUT pair (above) represent handshaking
between SNAX/APC and the SNA access method. These handshaking entries are not
relevant to tracing TP problems, and so all subsequent entries like the one shown above
have been edited out of the rest of the trace.
In this BIN, a positive response (+RSP) to the bid is received from the access method.
==============================================================================
<BIN> @mucb 849818 seq: 134 05/13/92 11:40:03.62
mucb:
OCB ID: %H0000
LU ID: %H0002; SESSION ID: %H0007
TPI ID: %H0071; CONV ID: %H0045
000CF79A 000CF79A 00500001 00020007 00450071
00070000 00000000 00000000 00000000 00000000
00000000 00000000 00000001
biu: SRPL RECEIVE SPECIFIC
SRPL=001B 0001 0000014E 00070000 60000000 0177 0000 0000 000E
RH=CB8200 +RSP DFC FI BCI ECI DR1 QRI
04 [.]
==============================================================================
<DOUT> @mucb 849702 seq: 182 05/13/92 11:40:03.66
mucb:
OCB ID: %H0008
LU ID: %H0002; SESSION ID: %H0007
TPI ID: %H0071; CONV ID: %H0045
000CF726 000CF726 00500002 00020007 00450071
00070000 0008000C F41A0000 00110502 00000000
00000000 00000000 0000001C
IPC HEADER:
request: ALL-UOWS-OK (0)
version: S2
return code: OK (0)
retn detail: OK (0)
rid: %H0039, %H0000, %H9438
uows in: 1
uows out: 1
00005332 00000000 00390000 94380001 00010000 [..S2.....9...8......]
UOWs:
verb: ALLOCATE
uow id: 1332
return code: 0000
retn detail: 0000
535403E9 00000000 [ST......]