SNAX/APC Configuration and Management Manual
Trace Analysis Program
SNAX/APC Configuration and Management Manual—138787
5-24
Error Version (Trace Format)
The RH contains all zeros. The BIN/BOUT pair (above) represent handshaking 
between SNAX/APC and the SNA access method. These handshaking entries are not 
relevant to tracing TP problems, and so all subsequent entries like the one shown above 
have been edited out of the rest of the trace. 
In this BIN, a positive response (+RSP) to the bid is received from the access method. 
==============================================================================
 <BIN>  @mucb 849818  seq:  134    05/13/92 11:40:03.62
 mucb:
 OCB ID: %H0000
 LU ID: %H0002; SESSION ID: %H0007
 TPI ID: %H0071; CONV ID: %H0045
 000CF79A 000CF79A 00500001 00020007 00450071
 00070000 00000000 00000000 00000000 00000000
 00000000 00000000 00000001
 biu: SRPL RECEIVE SPECIFIC
 SRPL=001B 0001 0000014E 00070000 60000000 0177 0000 0000 000E
 RH=CB8200 +RSP DFC FI BCI ECI DR1 QRI
 04       [.]
==============================================================================
 <DOUT> @mucb 849702  seq:  182    05/13/92 11:40:03.66
 mucb:
 OCB ID: %H0008
 LU ID: %H0002; SESSION ID: %H0007
 TPI ID: %H0071; CONV ID: %H0045
 000CF726 000CF726 00500002 00020007 00450071
 00070000 0008000C F41A0000 00110502 00000000
 00000000 00000000 0000001C
 IPC HEADER:
 request: ALL-UOWS-OK (0)
 version: S2
 return code: OK (0)
 retn detail: OK (0)
 rid: %H0039, %H0000, %H9438
 uows in:  1
 uows out:  1
 00005332 00000000 00390000 94380001 00010000 [..S2.....9...8......]
 UOWs:
 verb: ALLOCATE
 uow id: 1332
 return code: 0000
 retn detail: 0000
 535403E9 00000000     [ST......]