SNAX/APC Configuration and Management Manual
SCF Commands for SNAX/APC
SNAX/APC Configuration and Management Manual—138787
8-31
ALTER PTNR-MODE Command
RESPONSIBLE attributes can be altered when the PTNR-MODE is in the STOPPED
state.
ALTER PTNR-MODE Attributes
The attribute specification for the PTNR-MODE object of the SNAX/APC ALTER
command consists of the following attribute name and value combinations:
LIKE partner-mode2
identifies an existing PTNR-MODE object whose attribute values serve as the
model for the new values of the attributes of the PTNR-MODE object being altered.
DEFAULTMAXINRUSIZE number
alters the maximum size of normal flow request units (RUs) that the local LU can
receive over sessions started with this mode. Valid values are from 16 through
16,000. Although 16,000 is the maximum value allowed by SNAX/APC, the actual
maximum is 15,360. This is because SNAX/APC adjusts the value specified to the
closest RU size defined by SNA that is less than or equal to the specified value.
ALTER [ PTNR-MODE partner-mode1 ] [ , LIKE partner-mode2 ]
[ , attribute-spec ]
where attribute-spec is:
[ , DEFAULTMAXINRUSIZE number ] ++STOPPED state
only
[ , DEFAULTMAXOUTRUSIZE number ] ++STOPPED state
only
[ , DEFAULTMAXSESSION number ] ++STOPPED state
only
[ , DEFAULTMINCONLOSER number ] ++STOPPED state
only
[ , DEFAULTMINCONWINNER number ] ++STOPPED state
only
[ , MAXAUTOACT number ] ++STOPPED state
only
[ , MAXSESSION number ] ++STARTED state
only
[ , MINCONLOSER number ] ++STARTED state
only
[ , MINCONWINNER number ] ++STARTED state
only
[ , MODENAME modename ] ++STOPPED state
only
[ , RCVWINDOW number ] ++STOPPED state
only
[ , RESPONSIBLE { SOURCE | TARGET } ] ++STARTED state
only
[ , SENDWINDOW number ] ++STOPPED state
only