ALTER PTNR-MODE Command
RESPONSIBLE attributes can be altered when the PTNR-MODE is in the STOPPED 
state.
ALTER PTNR-MODE Attributes
The attribute specification for the PTNR-MODE object of the SNAX/APC ALTER 
command consists of the following attribute name and value combinations: 
LIKE partner-mode2
identifies an existing PTNR-MODE object whose attribute values serve as the 
model for the new values of the attributes of the PTNR-MODE object being altered.
DEFAULTMAXINRUSIZE number
alters the maximum size of normal flow request units (RUs) that the local LU can 
receive over sessions started with this mode. Valid values are from 16 through 
16,000. Although 16,000 is the maximum value allowed by SNAX/APC, the actual 
maximum is 15,360.  This is because SNAX/APC adjusts the value specified to the 
closest RU size defined by SNA that is less than or equal to the specified value.
ALTER [ PTNR-MODE partner-mode1 ] [ , LIKE partner-mode2 ]
 [ , attribute-spec ]
where attribute-spec is:
 [ , DEFAULTMAXINRUSIZE number ] ++STOPPED state 
only
 [ , DEFAULTMAXOUTRUSIZE number ] ++STOPPED state 
only
 [ , DEFAULTMAXSESSION number ] ++STOPPED state 
only
 [ , DEFAULTMINCONLOSER number ] ++STOPPED state 
only
 [ , DEFAULTMINCONWINNER number ] ++STOPPED state 
only
 [ , MAXAUTOACT number ] ++STOPPED state 
only
 [ , MAXSESSION number ] ++STARTED state 
only
 [ , MINCONLOSER number ] ++STARTED state 
only
 [ , MINCONWINNER number ] ++STARTED state 
only
 [ , MODENAME modename ] ++STOPPED state 
only
 [ , RCVWINDOW number ] ++STOPPED state 
only
 [ , RESPONSIBLE { SOURCE | TARGET } ] ++STARTED state 
only
 [ , SENDWINDOW number ] ++STOPPED state 
only