SNAX/APC Configuration and Management Manual
SCF Commands for SNAX/APC
SNAX/APC Configuration and Management Manual—138787
8-81
STATS PROCESS Command
Reset Time
displays the date and time that the statistics counters were last reset. The counters
can be reset by one of the following events:
•
The statistics counters were reset by the RESET parameter of the STATS
command.
•
The process was initiated.
•
A takeover by the backup process occurred.
Config Openers
displays the maximum allowed number of concurrent opens of the SNAX/APC
process. Note that 16 of the opens are reserved for use by the Subsystem
Programmatic Interface (SPI).
Max Openers
displays the maximum number of concurrent opens of the SNAX/APC process that
have been issued since the counters were last reset.
Current Openers
displays the current number of opens of the SNAX/APC process.
Config RCV Depth
displays the maximum number of unanswered requests that the operating system
allows in the receive queue.
Current RCV Depth
displays the current number of unanswered requests in the receive queue.
Max RCV Depth
displays the maximum number of unanswered requests that have been in the receive
queue since the counters were last reset.
Config MEM Pool
displays the maximum number of bytes that can be allocated from the memory
pool.
Current MEM Pool
displays the number of bytes currently allocated from the memory pool.
Max Allocated
displays the maximum number of bytes that have been allocated from the memory
pool since the SNAX/APC process was started.