SNAX/APC Configuration and Management Manual
Event Management
SNAX/APC Configuration and Management Manual—138787
E-17
6: ZAPC-EVT-INV-OP
6: ZAPC-EVT-INV-OP
An operational failure has been detected by SNAX/APC.
Message Parameter Descriptions
<1> equals ZCOM-TKN-SUBJ-PROC.
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER
is the event number. Its value is ZAPC-EVT-INV-OP.
ZEMS-TKN-CONSOLE-PRINT
contains the value ZSPI-VAL-TRUE, which specifies that the event message be
processed by the compatibility distributor.
ZEMS-TKN-EMPHASIS
contains the value ZSPI-VAL-TRUE, indicating that the event should be considered
critical to your operations environment.
ZCOM-TKN-SUBJ-PROC
is the name of the SNAX/APC process for which the event occurred.
Cause. SNAX/APC has detected an operational failure.
Effect. The process terminates abnormally.
Recovery. You need to seek additional help. Follow the procedures described at the
beginning of this appendix for collecting relevant information and contacting the
appropriate support personnel.
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-ENUM.
ZEMS-TKN-CONSOLE-PRINT token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZCOM-TKN-SUBJ-PROC token-type ZSPI-TYP-STRING.
Event-Message Text
<1>: Abending - SNAX/APC internal error