SNAX/APC Configuration and Management Manual

Event Management
SNAX/APC Configuration and Management Manual138787
E-54
36: ZAPC-EVT-SWITCHING-DB-FAILED
36: ZAPC-EVT-SWITCHING-DB-FAILED
The switch to a new configuration file has failed.
Message Parameter Descriptions
<1>equals ZCOM-TKN-SUBJ-PROC.
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER
is the event number. Its value is ZAPC-EVT-SWITCHING-DB-FAILED.
ZEMS-TKN-CONSOLE-PRINT
contains the value ZSPI-VAL-TRUE, which directs that the event message be
processed by the compatibility distributor.
ZEMS-TKN-EMPHASIS
contains the value ZSPI-VAL-FALSE, indicating that the event should not be
considered critical to your operations environment.
ZCOM-TKN-SUBJ-PROC
is the name of the SNAX/APC process for which the event occurred.
Cause. A configuration database file switch has failed.
Effect. If the switch failed because the old configuration database file was inaccessible,
SNAX/APC has no current database file. SNAX/APC will continue to perform
conversation related activities and to honor CNOS requests from the remote LU.
However, SNAX/APC will not honor any sensitive SPI (or SCF) commands. Any such
commands will be rejected with the error ZAPC-ERR-CONFIG-IS-BAD.
If the switch was prompted by an ALTER PROC command, and the original
configuration file is still accessible, the SNAX/APC process reverts to the original file as
its configuration database.
Recovery. This is an informational event only; the process continues.
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-ENUM.
ZEMS-TKN-CONSOLE-PRINT token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZCOM-TKN-SUBJ-PROC token-type ZSPI-TYP-STRING.
Event-Message Text
<1>: Switching configuration database - FAILED