SNAX/APC Management Programming Manual
INFO PROC
Commands and Responses
5–54 111813 Tandem Computers Incorporated
ZCMK-TKN-PROG-FILE-MOD
indicates the date upon which the program currently being executed as the
SNAX/APC process was last modified.
ZAPC-TKN-CONFIG-XFNAME
indicates the name of the file that contains the configuration information.
ZAPC-TKN-EMS-SUPPRESSION
records which events are currently being suppressed by SNAX/APC.
ZAPC-TKN-MAXINRUSIZE
indicates the maximum number of bytes allowed in an incoming request/response
unit (RU). The number displayed is the process-wide default; individual PTNR-
MODE objects may have different values.
ZAPC-TKN-MAXOUTRUSIZE
indicates the maximum number of bytes in an outgoing request/response unit
(RU). The number displayed is the process-wide default; individual PTNR-
MODE objects may have different values.
ZAPC-TKN-MAXAPPLIOSIZE
indicates the maximum number of bytes the SNAX/APC application can send to
or receive from the SNAX/APC process (that is, the maximum size of an IPC
message).
ZAPC-TKN-ONE-STEP-READ
indicates whether one step reads are used. The value ZSPI-VAL-TRUE indicates
that one step reads are allowed. The value ZSPI-VAL-FALSE indicates that one
step reads are not allowed; SNAX/APC uses the two-step read method when
reading from the underlying SNAX access method..
ZAPC-TKN-REMOTE-ATTACH-DISP
indicates whether remote Attach requests are queued or rejected.
ZAPC-TKN-REMOTE-ATTACH-TIMER
specifies the amount of time in milliseconds that SNAX/APC will wait for a
remote TP-READY to arrive to satisfy the Attach.