SNAX/APC Management Programming Manual
1: ZAPC-EVT-FSM-ERR
Event Management
6–10 111813 Tandem Computers Incorporated
1: ZAPC–EVT–FSM–ERR SNAX/APC encountered an unexpected finite state machine (FSM) error.
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-ENUM.
ZEMS-TKN-CONSOLE-PRINT token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZCOM-TKN-SUBJ-PROC token-type ZSPI-TYP-STRING.
ZAPC-TKN-FSM-NAME token-type ZSPI-TYP-ENUM.
ZAPC-TKN-STATE token-type ZSPI-TYP-INT.
ZAPC-TKN-FSM-EVT token-type ZSPI-TYP-INT.
Conditional Token
ZAPC-TKN-LU-NAME token-type ZSPI-TYP-STRING.
Event-Message Text
<1>
: State violation, [LU =
<2>
,] FSM =
<3>
, current state =
#
<4>
, current event = #
<5>
Message Parameter Descriptions
<1>
equals ZCOM–TKN–SUBJ–PROC.
<2>
equals ZAPC–TKN–LU–NAME.
<3>
equals ZAPC–TKN–FSM–NAME.
<4>
equals ZAPC–TKN–STATE.
<5>
equals ZAPC–TKN–FSM–EVT.
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER
is the event number. Its value is ZAPC–EVT–FSM–ERR.
ZEMS-TKN-CONSOLE-PRINT
contains the value ZSPI–VAL–TRUE, which directs that the event message be
processed by the compatibility distributor.
ZEMS-TKN-EMPHASIS
contains the value ZSPI–VAL–FALSE, indicating that the event should not be
considered critical to your operations environment.
ZCOM-TKN-SUBJ-PROC
is the name of the SNAX/APC process for which the event occurred.