SNAX/APC Management Programming Manual

6: ZAPC-EVT-INV-OP
Event Management
6–18 111813 Tandem Computers Incorporated
6: ZAPC–EVT–INV–OP An operational failure has been detected by SNAX/APC.
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-ENUM.
ZEMS-TKN-CONSOLE-PRINT token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZCOM-TKN-SUBJ-PROC token-type ZSPI-TYP-STRING.
Event-Message Text
<1>
: Abending - SNAX/APC internal error
Message Parameter Descriptions
<1>
equals ZCOM–TKN–SUBJ–PROC.
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER
is the event number. Its value is ZAPC–EVT–INV–OP.
ZEMS-TKN-CONSOLE-PRINT
contains the value ZSPI–VAL–TRUE, which specifies that the event message be
processed by the compatibility distributor.
ZEMS-TKN-EMPHASIS
contains the value ZSPI–VAL–TRUE, indicating that the event should be
considered critical to your operations environment.
ZCOM-TKN-SUBJ-PROC
is the name of the SNAX/APC process for which the event occurred.
Cause
SNAX/APC has detected an operational failure.
Effect
The process terminates abnormally.
Recovery
You need to seek additional help. Follow the procedures described at the beginning of
this appendix for collecting relevant information and contacting the appropriate
support personnel.