SNAX/APC Management Programming Manual
36: ZAPC-EVT-SWITCHING-DB-FAILED
Event Management
111813 Tandem Computers Incorporated 6–61
Cause
A configuration database file switch has failed.
Effect
If the switch failed because the old configuration database file was inaccessible,
SNAX/APC has no current database file. SNAX/APC will continue to perform
conversation related activities and to honor CNOS requests from the remote LU.
However, SNAX/APC will not honor any sensitive SPI (or SCF) commands. Any such
commands will be rejected with the error ZAPC-ERR-CONFIG-IS-BAD.
If the switch was prompted by an ALTER PROC command, and the original
configuration file is still accessible, the SNAX/APC process reverts to the original file
as its configuration database.
Recovery
This is an informational event only; the process continues.