SNAX/APC Management Programming Manual
37: ZAPC-EVT-CFG-DB-CONVERTED
Event Management
6–62 111813 Tandem Computers Incorporated
37: ZAPC–EVT–CFG-DB-CONVERTED
After a warm start, SNAX/APC automatically converts the configuration database
specified by the CONFIG attribute value to the current level.
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-ENUM.
ZEMS-TKN-CONSOLE-PRINT token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZCOM-TKN-SUBJ-PROC token-type ZSPI-TYP-STRING.
ZAPC-TKN-CONFIG-FILE token-type ZSPI-TYP-STRING.
Event-Message Text
<1>
: Configuration database has been converted to current
level; Old CONFIG file was renamed to
<2>
Message Parameter Descriptions
<1>
equals ZCOM–TKN–SUBJ–PROC.
<2> equals ZAPC–TKN–CONFIG-FILE.
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER
is the event number. Its value is ZAPC–EVT–CFG-DB-CONVERTED.
ZEMS-TKN-CONSOLE-PRINT
contains the value ZSPI–VAL–TRUE, which directs that the event message be
processed by the compatibility distributor.
ZEMS-TKN-EMPHASIS
contains the value ZSPI–VAL–FALSE, indicating that the event should not be
considered critical to your operations environment.
ZCOM-TKN-SUBJ-PROC
is the name of the SNAX/APC process for which the event occurred.
ZAPC-TKN-CONFIG-FILE
identifies the name of the new configuration file database.