SNAX/APC Management Programming Manual

Notation Used
Error Numbers and Error Lists
111813 Tandem Computers Incorporated A–3
Common Errors:
-00001 Through -00999
and -32nnn Series
Error messages with the prefix ZCOM- or ZCMK- are common to more than one
Tandem product. The ZCOM- errors have numbers ranging from -00001 through
-00999. Detailed information on both the ZCOM- and ZCMK- error numbers,
including errors that do not involve the SNAX/APC subsystem, can be found in the
SPI Common Extensions Manual.
Table A-1 contains a list of the standard ZCMK- data communications error codes that
are returned at the SNAX/APC subsystem level (this list is subject to change and may
not include all the ZCMK- errors that can be returned).
Table A-1. SCP Error Messages Generated by SNAX/APC
Error Symbolic Name (ZCMK-ERR-) Description
-32767 BKUP-IN-PRI-CPU Specified backup CPU is current primary.
-32765 CANT-ASGN File name cannot be assigned.
-32764 CANT-RMT File name cannot be a remote file.
-32763 BKUP-NOT-INIT Backup process is not initialized.
-32762 NO-CHARMAP No character map was specified
-32761 BAD-CHARMAP Invalid character map was specified
-32760 CANT-ALLOC-SEG Specified segment cannot be allocated.
Notation Used Each error-list description on the following pages contains a box that lists all the
tokens that can appear in the error list, including the tokens ZSPI–TKN–ERRLIST and
ZSPI–TKN–ENDLIST, which start and end all error lists. With the exception of
ZSPI-TKN-ERRLIST and ZSPI–TKN–ENDLIST, the order of the tokens in the box is
not necessarily the order in which they actually occur.
The notation used in the box for simple tokens is a shorthand version of the essential
information given in the DDL TOKEN–CODE statement.