SNAX/APC Management Programming Manual

6: ZAPC-ERR-CMD-FORCED
Error Numbers and Error Lists
A–10 111813 Tandem Computers Incorporated
6: ZAPC-ERR-CMD-FORCED
The CNOS command was processed as a FORCED option. No error list is generated.
Cause
An error condition prevented the successful exchange of the CNOS request and reply,
and the CNOS conversation either failed or was rejected by the partner LU. The
selection of the FORCE option forced the local LU to reset its partner-mode session
limit. The equivalent RETURN_CODE value, as defined in the IBM Transaction
Programmer's Reference Manual for LU 6.2, is OK - AS_FORCED.
The error is caused by an ABORT PTNR-MODE or STOP PTNR-MODE command.
Effect
The CNOS conversation either fails or is rejected by the partner LU.
Recovery
None: this message is a warning that the PTNR-MODE object has aborted.