SNAX/APC Management Programming Manual
14: ZAPC-ERR-DUP-MODENAME
Error Numbers and Error Lists
A–18 111813 Tandem Computers Incorporated
14: ZAPC-ERR-DUP-MODENAME
A duplicate MODENAME value was specified.
ZSPI–TKN–ERRLIST token–type ZSPI–TYP–LIST.
ZSPI–TKN–ERROR token–type ZSPI–TYP–ERROR.
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-STRING
ZSPI–TKN–ENDLIST token–type ZSPI–TYP–SSCTL.
ZSPI–TKN–ERROR
is the standard SPI error token, as described in the SPI Programming Manual. Its
value consists of the subsystem ID and the error number found in the ZAPC–ERR–
DUP–MODENAME token. ZSPI–TKN–ERROR is always present in the error list.
ZCOM-TKN-OBJNAME
is the first object name provided with the command on which the error occurred.
This token is always present in the error list, and is described in Section 4,
“Common Definitions.”
ZCOM-TKN-OBJTYPE
is the object type provided with the command on which the error occurred. This
token is always present in the error list, and is described in Section 4, “Common
Definitions.”
Cause
An existing PTNR-MODE object has the same mode name as the one specified in the
ADD PTNR-MODE command.
Effect
The ADD PTNR-MODE command fails.
Recovery
Change the mode name in the ADD PTNR-MODE command and retry.