28: ZAPC-ERR-SUB-NOT-DELETED
Error Numbers and Error Lists
111813 Tandem Computers Incorporated A–33
28: ZAPC-ERR-SUB-NOT-DELETED
Subordinate objects were not deleted.
ZSPI–TKN–ERRLIST token–type ZSPI–TYP–LIST.
ZSPI–TKN–ERROR token–type ZSPI–TYP–ERROR.
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-STRING
ZSPI–TKN–ENDLIST token–type ZSPI–TYP–SSCTL.
ZSPI–TKN–ERROR
is the standard SPI error token, as described in the SPI Programming Manual. Its
value consists of the subsystem ID and the error number found in the ZAPC–ERR–
SUB–NOT–DELETED token. ZSPI–TKN–ERROR is always present in the error
list.
ZCOM-TKN-OBJNAME
is the first object name provided with the command on which the error occurred.
This token is always present in the error list, and is described in Section 4,
“Common Definitions.”
ZCOM-TKN-OBJTYPE
is the object type provided with the command on which the error occurred. This
token is always present in the error list, and is described in Section 4, “Common
Definitions.”
Cause
This error was caused by an attempt to delete an LU, PTNR-LU, PTNR-MODE, or TPN
object while one or more of its subordinates existed.
Effect
Subordinate objects are not deleted.
Recovery
Specify the SUB parameter with the command or make sure all subordinate objects are