SNAX/APC Management Programming Manual
ZAPC-TKN-TERMINATION-CNT
Common Definitions
4–44 111813 Tandem Computers Incorporated
ZAPC-TKN-TERMINATION-CNT
specifies the number of sessions that need to be terminated. Valid values range
from 0 to 1024.
The TEMINATION-CNT token has the token type ZSPI-TYP-INT. The
programmatic commands that use this token are ZCOM-CMD-INFO and ZCOM-
CMD-STATUS. The valid object type for this token is PTNR-MODE.
This token is always returned in the ZCOM-CMD-INFO and ZCOM-CMD-
STATUS response buffers.
ZAPC-TKN-TPI-ORIGIN
specifies where the instance of the transaction program (TPI) originated: at the
local LU or the remote LU.
The TPI-ORIGIN token has the token type ZSPI-TYP-ENUM. The programmatic
command that uses this token is ZCOM-CMD-INFO. The valid object type for this
token is TPI.
The following enumerated values are valid for this token:
ZAPC-VAL-TPI-ORIGIN-LOCAL
specifies that the TPI originated at the local LU.
ZAPC-VAL-TPI-ORIGIN-REMOTE
specifies that the TPI originated at the remote LU.
This token is always returned in the ZCOM-CMD-INFO response buffer.
ZAPC-TKN-TRC-OPT
specifies what information about the traced object is to be collected. Generally, it
is advisable to specify all options (ZAPC-VAL-TRC-OPT-ALL) for tracing. This
token can occur multiple times.
The TRC-OPT token has the token type ZSPI-TYP-ENUM. The programmatic
command that uses this token is ZCOM-CMD-TRACE. The valid object types for
this token are LU and PROC.
The following enumerated values are valid for this token:
ZAPC-VAL-TRC-OPT-ALL
selects all of the trace options that follow. This is the default value for ZAPC-
TKN-TRC-OPT.
ZAPC-VAL-TRC-OPT-DATA
traces data sent between transaction programs and SNAX/APC.
ZAPC-VAL-TRC-OPT-BIU
traces basic information units (BIUs) sent to and received from SNAX/XF LU
objects or SNAX/CDF APPL objects.