SNAX/APN Application Programming Manual

Handling Errors in SNAX/APN Applications
SNAX/APN Application Programming Manual420111-001
B-4
File-System Error Codes
123 (%173) ITI PRT CRT SNALU Subdevice busy The subdevice has returned sense
code x'082D' or x'0814,' or status
sense DB (device busy). The
printer might have a full buffer
and be unable to accept any more
data. Retry the operation.
A second possibility is that an
open request was received while a
close request was being
processed. Retry the open.
A third possibility is that a
CONTROL-12 was received from
a process-pair to disconnect a line
that has two or more opened LUs.
137 (%211) Controller buffer
parity
A parity error occurred in the
controller buffer. Notify your
system operator.
139 (%213) Controller error A controller failed its internal
diagnostics. Retry the operation;
if it fails again, notify your system
operator.
140 (%214) ITI PRT CRT SNALU Modem, line, PU,
LU, or other such
error
Session lost; the failed request
might be due to problems with
such things as the modem, line,
PU, or LU. Reestablish the
session and retry your request.
160 (%240) Invalid state
161 (%241) All PT No PT session A passthrough request was denied
because the passthrough partner
LU is not available.
175 (%257) All Data link failure An SDLC FRMR response was
received from a PU on a primary
line or sent by a PU on a
secondary line.
177 (%261) ITI CRT SNALU Text overrun The requested transfer count is
less than the actual count
transferred and the buffer has
been overrun.
179 (%263) ITI PRT CRT Invalid SNA input A COMMAND REJECT,
OPERATION CHECK, or other
negative response was received
from the device.
Table B-1. File-System Error Codes (page 3 of 4)
Error Number Type Meaning Possible Cause/Solution