SNAX/HLS Configuration and Control Manual
Command Dictionary
Using the HLSRDT Utility
104705 Tandem Computers Incorporated 4-25
@SHOW BIND
BIND:
bind_type: NONNEGOTIABLE lu_session_type: 2
fm_profile: 3 ts_profile: 3
pri_chain_use: MULTIPLE_RU sec_chain_use: MULTIPLE_RU
pri_rq_mode: IMMEDIATE sec_rq_mode: IMMEDIATE
pri_chain_protocol: EXCEPTION sec_chain_protocol: DEFINITE
pri_two_phase_commit: NO sec_two_phase_commit: NO
pri_compression_ind: NO sec_compression_ind: NO
pri_eb_send: YES sec_eb_send: NO
pri_send_pacing_size: 0 sec_send_pacing_size: 0
pri_send_staging NO sec_send_staging NO
pri_recv_pacing_size: 0 sec_recv_pacing_size: 0
pri_max_ru: 1024 sec_max_ru: 1024
no_segments: NO fm_header_use: NO
brkt_reset: BETB brkt_term: CONDITIONAL
alt_code_use: NO seqno_use: NO
bis_sent: NO bind_queuing: NO
send_recv: HDUX_FF recovery_mode: LOSER
contention_winner: SECONDARY alt_code_id: ASCII_7
hdx_ff_reset_sender: SECONDARY
ps_usage: 0000000000185000007E00
plu_name: user_data: ""
@
The following SHOW INIT command produces a formatted listing of the values
currently defined in the INIT working image.
@SHOW INIT
INIT:
mode_name: appl_name:
requester_id: "REQ-ID" password: "PASS-WRD"
user_data: "This is data"
@