HLSCOM Error Messages
104705 Tandem Computers Incorporated B–7
Token
token
is required and is missing
Cause. The HLSCOM program did not include all tokens required for a command.
Effect. The command fails.
Recovery. Retry the command. If the error persists, consult your Tandem analyst.
Tokens
token1
and
token2
have conflicting values
Cause. The HLSCOM program encountered two tokens whose values should have
been in agreement, but were not.
Effect. The command fails.
Recovery. Retry the command. If the error persists, consult your Tandem analyst.
Tracing already active
Cause. You attempted to start tracing when tracing was active already.
Effect. The command fails.
Recovery. If you want to start a new trace, stop the active trace and start a new one.
Version incompatibility
Cause. The HLSCOM program attempted to send a SPI message to a server that was
using an incompatible version of Distributed System Management (DSM).
Effect. The command fails.
Recovery. Check the versions of DSM and servers on your systems.