SNAX/XF and SNAX/APN Configuration and Management Manual

SCF Commands for SNAX/XF and SNAX/APN
SNAX/XF and SNAX/APN Configuration and Management Manual425836-006
13-72
NAMES Command
The names given in the left-hand column of the display are the names of the objects
about which information is being reported. The column headings identify the object
type for each set of objects.
All other INFO SUBSYS display fields are described in Section 14, Attributes for
SNAX/XF and SNAX/APN.
Note that this example corresponds to the subsystem configured in the examples listed
under the ADD command.
NAMES Command
The NAMES command retrieves the names of objects subordinate to the specified
object. It is a nonsensitive command.
OUT file-spec
causes any SCF output generated for this command to be directed to the specified
file. file-spec must be a partially or fully qualified file name. If this option is not
specified, the output is sent to the home terminal.
object-name
is the name of the object whose subordinate objects are to be named.
SUB [ subtype ]
selects the subordinate objects the command affects. subtype can be a
subordinate object type or one of the keywords ONLY, ALL, or NONE.
If a subordinate object type is named, only objects of that type are affected. ONLY
specifies that only the subordinate objects are affected. ALL specifies that the
named object and the subordinate objects are affected. NONE specifies that the
named object is affected but none of the subordinate objects are affected. If the
SUB option is omitted or if subtype is omitted, ALL is assumed.
The SUB option is not valid for APPL or LU objects.
NAMES [ / OUT file-spec / ] { APPL }
{ LINE }
{ LU }
{ PU }
{ SUBSYS }
{ object-name }
{ ( object-name [, object-name ]... ) }
[, SUB [ subtype ] ] [, SEL [ NOT ] state ]