X21T5TIMEOUT
The valid range of values for this attribute is 0 through 10 minutes, 5 seconds, and 35
hundredths of a second (0 through 10:5.35). If the value specified is 0, ADCCP does
not use the specific T4 timer during the X.21 call establishment process.
X21T5TIMEOUT
This attribute only applies to unsupported X.21 switched lines. The attribute description
is given because the attribute appears in SCF INFO LINE, DETAIL displays.
X21T5TIMEOUT specifies the T5 time limit that the X.21 DTE uses when waiting for a
DCE response during call establishment. T5 represents the T5 timer. This attribute
applies only to SDLC lines.
The valid range of values for this attribute is 0 through 10 minutes, 5 seconds, and 35
hundredths of a second (0 through 10:5.35). If the value specified is 0, ADCCP does
not use the specific T5 timer during the X.21 call establishment process.
X21T6TIMEOUT
This attribute only applies to unsupported X.21 switched lines. The attribute description
is given because the attribute appears in SCF INFO LINE, DETAIL displays.
X21T6TIMEOUT specifies the T6 time limit that the X.21 DTE uses when waiting for a
DCE response during call establishment. T6 represents the T6 timer. This attribute
applies only to SDLC lines.
The valid range of values for this attribute is 0 through 10 minutes, 5 seconds, and 35
hundredths of a second (0 through 10:5.35). If the value specified is 0, ADCCP does
not use the specific T6 timer during the X.21 call establishment process.
X21T7TIMEOUT
This attribute only applies to unsupported X.21 switched lines. The attribute description
is given because the attribute appears in SCF INFO LINE, DETAIL displays.
Default: 2 seconds
Value: 0 - 10:55.35
Objects: LINE
Default: 2 seconds
Value: 0 - 10:55.35
Objects: LINE
Default: 0.2 seconds
Value: 0 - 10:55.35