Line-Handler Trace Records
Line-Handler Trace Records
The following pages describe the trace records generated by the line handler for all
types of lines.
003: PIU^TRACE^ID (PIU In)
This trace record contains the inbound path information unit (PIU) received by SNAX
level 3 from SNAX level 2.
This trace record consists of the transmission header (TH), the request/response
header (RH), and the request/response unit (RU).
PU index nnn
gives the physical unit (PU) address.
PIU bytes: nn
gives the number of bytes in the PIU. This is the total length of the PIU, even if a
small RECSIZE value in the TRACE command caused the data in the trace record
to be truncated.
FID2 OIS EFI OAF(02) DAF(01) SEQ #0
is a symbolic representation of the contents of the transmission header (TH), using
the standard IBM abbreviations. This line can include the following abbreviations:
The TH shown above is for a FID2 PIU with mapping field set to only in segment
(only in chain). The origin/destination assignor indicator bit is 0, and the expedited
Record Type : 003 PIU^TRACE^ID
PIU In for PU index 200. PIU bytes: 12
FID2 OIS EFI OAF(02) DAF(01) SEQ #0
REQ FMD FI BC EC DR1I RU: 710306
2D00 0102 0000 0B80 0071 0306 !- q !
!
FIDn Format identification n (almost always, FID2; the field
descriptions below assume FID2)
FIS, LIS, MIS,
or OIS
Mapping field: first in segment, last in segment, middle in
segment, or only in segment
ODAI Origin/destination assignor indicator (if this abbreviation is
present, the ODAI bit is 1; if absent, the bit is 0)
EFI Expedited flow indicator (if this abbreviation is present, the EFI
bit is 1; if absent, the bit is 0)
OAF(n) Origin address field (n is the value of the field)
DAF(n) Destination address field (n is the value of the field)
SEQ #n Sequence number field (n is the value of the field)