SNAX/XF and SNAX/APN Configuration and Management Manual

SNAX/XF and SNAX/APN BINDs
SNAX/XF and SNAX/APN Configuration and Management Manual425836-006
B-3
Custom BINDs
PSERVIC Values for 3275 and 3276 Devices
PSERVIC Values for 3277 and 3278 Devices
Custom BINDs
This subsection explains how to customize the BIND image that SNAX/XF or
SNAX/APN sends (rather than using the default).
1. Use SNAXUTL to define a BIND table and entry; for example:
BEGIN
SELECTFILE $SYSTEM.SYS01.LOGTAB1, TYPE LOGMODE
ALLOCATE 10
ADD LOGMODENT BIND1, TYPE %H01, &
FMPROF %H03, &
TSPROF %H03, &
PRIPROT %H01, &
SECPROT %H90, &
COMPROT %H0380, &
SSNDPAC %H00 &
SRCVPAC %H00 &
RUSIZES %H8989 &
PSNDPAC %H00, &
PSERVIC %H020000000000185018507F00, &
ENCR %H00, &
PLUNAME “APPL1”, &
USERDATA (%HC1,%HC3,”DEPT 103”)
END
For more information about the parameters, see BIND Parameters
on page B-5.
Byte Device/Model(s)
3275/11 3275/12 3276/2/12 3276/3/13 3276/4/14
20 %H0C %H18 %H18 %H18 %H18
21 %H28 %H50 %H50 %H50 %H50
22 %H0C %H18 %H18 %H20 %H2B
23 %H50 %H50 %H50 %H50 %H50
24 %H7F %H02 %H7F %H02 %H7F
Byte Device/Model
3277/1 3277/2 3278/1 3278/2 3278/3 3278/4 3278/5
20 %H0C %H18 %H0C %H18 %H18 %H18 %H18
21 %H50 %H50 %H28 %H50 %H50 %H50 %H50
22 %H0C %H18 %H0C %H18 %H20 %H2B %H1B
23 %H50 %H50 %H50 %H50 %H50 %H50 %H84
24 %H7F %H02 %H7F %H02 %H7F %H7F %H7F