SNAX Error 00039
SNAX Error 00039
Cause. A PRIMARY command was issued to change the primary processor for the
service manager while an application was active. When an application is active, the
primary and backup CPUs for the service manager cannot be switched.
Effect. The PRIMARY command fails.
Recovery. Stop the application and reissue the command.
SNAX Error 00040
Cause. An invalid CPU number was specified in a PRIMARY command. The current
backup CPU must be specified as the new primary CPU.
Effect. The PRIMARY command fails.
Recovery. Retry the command using the CPU number of the current backup CPU.
SNAX Error 00041
Cause. An ALLOWOPENS or STOPOPENS command was issued for a switched
floating LU not currently connected to a line. A switched floating LU must be connected
to a line before its open state can be changed.
Effect. The command fails.
Recovery. Wait until the LU is temporarily subordinated to a line before issuing the
command. Note that a switched floating LU becomes temporarily subordinated to a line
only when a dial-in call is received; there is no way to subordinate a switched floating
LU to a line directly.
SNAX Error 00042
Cause. Both the PROGRAM and the PROG9370 attributes were specified in an ADD
LINE or ALTER LINE command. These two attributes are mutually exclusive.
Effect. The command fails.
Recovery. Retry the command, specifying only one of the two attributes.
SNAX E-00039 Application is active: object-name
SNAX E-00040 Invalid Cpu Number for object-name
SNAX E-00041 Floating Lu not connected: object-name
SNAX E-00042 Both PROG and PROG9370 were specified as