SNAX Error 00110SNAX Error 00110
Recovery. First, use the SETMANAGER command to determine the service manager
to which the line was added, then reissue the command that caused error. If you want
to add the line to a different service manager, first delete the line, then add it to a
different service manager.
SNAX Error 00110
Cause. The error occurs when using multiple service managers if the object name
does not match the service manager’s name.
Effect. The command fails.
Recovery. Issue the SETMANAGER command to determine the name of the
associated service manager.
SNAX Error 00111
Cause. The error occurs when using multiple service managers if the object name
was not found under the service manager specified.
Effect. The command fails.
Recovery. First, verify that the device was added, then verify the correct object name.
Issue the SETMANAGER command to determine the name of the service manager to
which the device was added, and re-issue the command that caused the error.
SNAX Error 00112
Cause. The NODETYPE value specified is not NONE, LEN or EN.
Effect. The command fails.
Recovery. Specify the proper value.
SNAX E-00110 Object \system-name.$service-manager-name.
[ object-name ] conflicts with Service Manager
\system-name.$service-manager-name
SNAX E-00111 Object \system-name.$service-manager-name.
[ object-name ]
not added to Service Manager
\system-name.$service-manager-name
SNAX E-00112 NODETYPE value is not supported.