122: ZSX1-EVT-WRONG-PU-MODE
ZEMS-TKN-CONSOLE-PRINT
contains the value ZSPI-VAL-FALSE. This token is described in the EMS Manual.
ZSPI-TKN-MANAGER
is the name of the service-manager process (the SUBSYS object name), as described
in Section 3 of the SNAX/XF Management Programming Manual.
ZSX1-TKN-REQ-OR-RESP
specifies whether an RU is a request or a response.
ZSX1-TKN-PIU
is the path information unit (PIU) in hexadecimal digits.
ZSX1-TKN-STA-MODE
indicates whether the line is acting as a primary or a secondary station. This token is
described in Section 4, “Common Definitions” in the SNAX/XF Management
Programming Manual
Cause. The service manager received a PIU from a PU on a primary line, or a gateway
PU received a PIU from a host system. The PU is not in the correct mode to send or
receive this kind of PIU.
For example, the service manager might have received an ACTPU request from an
outboard PU, or it might have received a response to an ACTPU request from an inboard
PU.
This event might indicate an inconsistency between the service-manager process and the
line-handler process.
Effect. The service manager rejects the PIU and continues processing.
Recovery. Abort and delete the PU, then add the PU and its configuration.