SNAX/XF and SNAX/APN Event Management Programming Manual

SNAX/XF Event Messages
SNAX/XF and SNAX/APN Event Management Programming Manual426859-001
3-4
-4: ZCOM-EVT-IO-FATAL-ERR
ZEMS-TKN-EMPHASIS
contains the value ZSPI-VAL-TRUE, indicating that this event is a critical event.
This token is described in the EMS Manual.
ZEMS-TKN-CONSOLE-PRINT
contains the value ZSPI-VAL-TRUE. This token is described in the EMS Manual.
ZSPI-TKN-MANAGER
is the name of the service-manager process (the SUBSYS object name), as described
in Section 3 of the SNAX/XF Management Programming Manual.
ZEMS-TKN-LDEV and ZEMS-TKN-LDEVNAME
are standard EMS tokens described in the EMS Manual.
ZEMS-MAP-EXIOADDR
is an extensible structured token that holds the extended physical address for the I/O
device associated with the event message. For more information, see the
EMS Manual.
ZCOM-TKN-FATAL-ERR-CAUSE
is a standard SPI common extensions token whose possible values are described in
the following paragraphs under “Cause, Effect, and Recovery.
Cause, Effect, and Recovery
The probable cause of this event, its effect on the system, and the action Compaq
recommends that you take to remedy it depend on the value contained in ZCOM-TKN-
IO-FATAL-ERR-CAUSE:
-17: ZCOM-VAL-IO-ERR-IOPUT
Cause. SNAX/XF received an error code while calling the IOPUT internal procedure.
This message is generated by the line handler.
Effect. SNAX/XF terminates.
Recovery. Contact the Global Customer Support Center (GCSC) and provide all
relevant information as follows:
Descriptions of the problem and accompanying symptoms
Details from the message(s) generated
Supporting documentation such as Event Management Service (EMS) logs, trace
files, and a CPU dump, if applicable
If your local operating procedures require contacting the Global Customer Support
Center (GCSC), please also supply your system number and the numbers and
versions of all related products.