SNAX/XF and SNAX/APN Event Management Programming Manual
SNAX/XF Event Messages
SNAX/XF and SNAX/APN Event Management Programming Manual—426859-001
3-20
7: ZSX1-EVT -CONMGR-INACT
7: ZSX1-EVT -CONMGR-INACT
The Concentrator Manager was not in a STARTED state when the SNAX/XF Line
Handler attempted to communicate with it.
Message Parameter Descriptions
param1 equals ZCOM-TKN-SUBJ-LINE.
param2 equals ZSX1-TKN-CONMGR-NAME
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER
is the event number. Its value is 7.
ZEMS-TKN-SUBJECT-MARK
is the standard EMS token that always immediately precedes the subject token.
ZCOM-TKN-SUBJ-LINE
is the fully qualified name of the line-handler process for the line on which the event
occurred.
ZEMS-TKN-EMPHASIS
contains the value ZSPI-VAL-FALSE indicating that this event is not a critical
event. This token is described in the EMS Manual.
ZEMS-TKN-CONSOLE-PRINT
contains the value ZSPI-VAL-TRUE. This token is described in the EMS Manual.
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-ENUM.
ZEMS-TKN-SUBJECT-MARK token-type ZSPI-TYP-MARK.
ZCOM-TKN-SUBJ-LINE token-type ZSPI-TYP-STRING.
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-CONSOLE-PRINT token-type ZSPI-TYP-BOOLEAN.
ZSPI-TKN-MANAGER token-type ZSPI-TYP-FNAME32.
ZEMS-TKN-LDEVNUMBER token-type ZSPI-TYP-INT2.
ZEMS-TKN-XLDEVNAME token-type ZSPI-TYP-STRING.
ZEMS-TKN-LDEV token-type ZSPI-TYP-UINT.
ZSX1-TKN-CONMGR-NAME token-type ZSPI-TYP-STRING.
Event-Message Text
SNAX Line Handler param1 was unable to communicate with
CONMGR param2