SNAX/XF LU Network Services Manual
Messages and Codes
ESS System Messages
B–4 097841 Tandem Computers Incorporated
" SESSION NOT BOUND --> S0007 "
Cause
LUNS was unable to process the failing command because of a resource problem.
Effect
The failing command is ignored and the terminal’s keyboard is reset to allow the
entry of another command. Additional information can be found in EMS event
message 81 (LUNS error code 2305, 2307, 2309, 2311, 2320, 2325, or 2326).
Recovery
Check EMS event message 81 for LUNS error code 2305, 2307, 2309, 2311, 2320,
2325, or 2326 and consult its description in the Operator Messages Manual for the
appropriate recovery action.
" INSUFFICIENT STORAGE--> S0008 "
Cause
LUNS was unable to process the failing command because it was unable to
allocate a memory segment or get a buffer from the buffer pool.
Effect
The failing command is ignored and the terminal’s keyboard is reset to allow the
entry of another command. Additional information can be found in EMS event
message 81 (LUNS error code 2307).
Recovery
Check EMS event message 81 for LUNS error code 2307 and consult its description
in the Operator Messages Manual for the appropriate recovery action.