SNAX/XF LU Network Services Manual

Messages and Codes
ESS System Messages
097841 Tandem Computers Incorporated B–11
" ESS ENTRY NOT FOUND END-OF-TABLE MARKER MISSING--> S0026 "
Cause
When the terminal’s ESS table was searched for a record whose record name
matches the failing command, the record was not found, nor was the end of table
marker found. This indicates that the table’s object file has been corrupted.
Effect
The failing command is ignored and the terminal’s keyboard is reset to allow the
entry of another command, but the terminal might not be able to use LUNS until
the problem is corrected.
Recovery
Save the terminal’s corrupted ESS table object file by renaming it and noting its
new name. The name of the ESS table object file is the ESS table name with the
letter O appended (for example, ESSTAB1’s object file name is ESSTAB1O). If
necessary, see “Finding an Assigned ESS Table” earlier in this appendix.
Rebuild the ESS table using SNAXUTL and retry the command. If the problem
persists with a new ESS table object file, the table’s corruption is a persistent
problem and requires more immediate attention. In either case, inform your
Tandem representative.
" APPLICATION NOT DEFINED --> S0027 "
Cause
An attempt was made to log on to a Tandem application that has not been defined
by an SCF ADD APPL command.
Effect
The failing command is ignored and the terminal’s keyboard is reset to allow the
entry of another command.
Recovery
Check the terminal’s ESS table for an ESSCMD record whose command name
matches the failing command. That record should contain a PLUNAME
specification that begins with a pound sign (#), and this is the name of the
application that has not been properly defined to LUNS by an SCF ADD APPL
command. If necessary, see “Finding an Assigned ESS Table” earlier in this
appendix.
Either use SNAXUTL to correct the PLUNAME specified in the ESSCMD record or
define the application to LUNS using an SCF ADD APPL command.