SNAX/XF LU Network Services Manual
Numbered Creator Process Messages
Creator Process Error Messages
C–4 097841 Tandem Computers Incorporated
Creator Process Error 006MIS
CP006MIS - ++++ Creator terminating ++++
Cause
This is probably due to incorrect startup parameters.
Effect
The Creator process is in a state from which it cannot recover. Note that this
message is accompanied by another message containing informative user data.
Recovery
Examine the accompanying message and correct any parameters that are in error.
Restart the Creator process.
Creator Process Error 007
This error message is no longer used.
Creator Process Error 008NEW
CP008NEW - CPU number too large or CPU parm is incorrect
Data =
user-data
Tandem Name =
Tandem-name
Cause
A user tried to start a new TACL, but the CPU number specified in the logon
record is either incorrect or too large.
Effect
A display of the current CONCDATA field parameters from the logon record of
the ESS table is returned as
user-data
. The
Tandem-name
value is returned in
the form $
line-name.
#
lu-name
.
Recovery
Use SNAXUTL to correct the logon record. Have the user restart the TACL
process.