SNAX/XF LU Network Services Manual

Numbered Creator Process Messages
Creator Process Error Messages
C–22 097841 Tandem Computers Incorporated
Creator Process Error 060NEW
CP060NEW - No keyword after comma in user data
Data =
user-data
Tandem Name =
Tandem-name
Cause
A comma was found as the last item in the logon record. The comma must be
followed by another parameter or excluded.
Effect
A display of the current CONCDATA field parameters from the logon record of
the ESS table is returned as
user-data
. The
Tandem-name
value is returned in
the form $
line-name.
#
lu-name
.
Recovery
Use SNAXUTL to correct the logon record. Have the user reissue the logon.
Creator Process Error 061NEW
CP061NEW - Expecting dollar sign as the first character
in the process name
Data =
user-data
Tandem Name =
Tandem-name
Cause
The process name specified in the DATA field of the logon record does not begin
with a dollar sign ($).
Effect
The
user-data
value is the user-supplied parameters from the DATA field in the
logon record. The
Tandem-name
value is returned in the form $
line-
name.
#
lu-name
.
Recovery
Use SNAXUTL to correct the logon record. Have the user reissue the logon.