SNAX/XF LU Network Services Manual
Numbered Creator Process Messages
Creator Process Error Messages
C–30 097841 Tandem Computers Incorporated
Creator Process Error 076INI
CP076INI - MAXPATHMONOPENS value not between 0 and 99
Cause
A MAXPATHMONOPENS value was specified that was not a number between 0
and 99.
Effect
The user was not allowed to log on to a Pathway application.
Recovery
Restart the Creator process using a value that is between 0 and 99.
Creator Process Error 077NEW
CP077NEW - Pathway access not allowed, MAXPATHMONOPENS = 0
Cause
The Creator process was started with a MAXPATHMONOPENS value of 0. The
user then tried to log on to a Pathway application.
Effect
The user was not allowed to log on to a Pathway application.
Recovery
Either restart the Creator process with a MAXPATHMONOPENS value greater
than 0, or inform the user that Pathway access is not allowed.
Creator Process Error 078
This error message is no longer used.
Creator Process Error 079
This error message is no longer used.