SNAX/XF LU Network Services Manual
Numbered Creator Process Messages
Creator Process Error Messages
097841 Tandem Computers Incorporated C–31
Creator Process Error 080INI
CP080INI - MAXSESSIONS value not between 1 and 2000.
Cause
The parameter for MAXSESSIONS was not between 1 and 2000 when using
D-series system software.
Effect
The Creator process logs the message and then stops executing.
Recovery
At startup, specify a value for the keyword MAXSESSIONS that is between 1 and
2000 when using D-series system software. (The value should be between 1 and
2000 when using the CRT and ITI protocols, and between 1 and 1000 when using
the SNALU protocol.)
Creator Process Error 081INI
CP081INI - ALLOCATESEGMENT failure
Status =
error field
Cause
The disk from which the Creator process was taken is out of space.
Effect
The value for
error field
is the error code returned from the call to
ALLOCATESEGMENT.
Recovery
Move the object file to another disk, or use the SWAP
disk
keyword on startup.