SNMP Configuration and Management Manual
TCP/IP Subagent
SNMP Configuration and Management Manual—424777-006
8-89
1008: ZTSA-EVT-EMSCOLL-OBJ-UNAVAIL
ztsaEmsCollectorName
is the name of the underlying process whose failure caused the interface between
the TCP/IP Subagent and the EMS collector to go out of service. The name of the
EMS collector process specified for the subagent’s private ztsaEmsCollectorName
MIB object is inserted in the message text following “underlying object.”
This information is displayed only if the value of the ZEMS-TKN-CHANGE-
REASON is ZEMS-VAL-UNDERLYING-FAILED.
code-location/internal-context-text
Indicates where in the subsystem or application code the fault occurred.
ZEMS-VAL-NULL
Indicates the type of subsystem defined event. Because the TCP/IP Subagent
process has not defined this as a private event, the DDL AS clause “undefined”
always appears in the message text following “user content.”
Cause. The subagent lost its connection to the configured EMS collector process
(ztsaEmsCollectorName).
Effect. Events generated by the subagent are discarded until the EMS collector
interface is returned to a connected state. The subagent attempts to reacquire the
EMS collector connection whenever the subagent attempts to generate an event
message.
Recovery. Check the operating state of the EMS collector process
(ztsaEmsCollectorName).
Sample Message
96-02-08 11:31:35 \NOVA.$ZTSA TANDEM.TCPIPSA.D20 001008
Object unavailable emscollector-interface -
\NOVA.$p0, event number: emscollector-
interface-unavailable,
cause: underlying-serv-failed,
previous state: connected,
current state: disconnected,
underlying object: \NOVA.$p0,
symptom string: T7862D20_01JAN96_TCPIPSA:,
user content: undefined
96-02-08 12:03:00 \NOVA.$ZTSA TANDEM.TCPIPSA.D20 001008
Object unavailable emscollector-interface -
\NOVA.$p0, event number: emscollector-
interface-unavailable,
cause: operator-initiated,
previous state: connected,
current state: disconnected,
user content: undefined