SNMP Configuration and Management Manual
EMS Trap Subagent
SNMP Configuration and Management Manual—424777-006
9-15
The EMS Trap MIB
trapSubject
1.3.6.1.4.1.169.3.12.4)
 not-accessible
 DisplayString (SIZE
 (1..50))
The hardware or 
software component 
most directly involved 
in the event.
All values except 
floating-point values and 
values stored as 
structured tokens can be 
formatted. A question 
mark (?) appears when 
the value of the subject 
cannot be formatted.
The value of the first 
event subject token.
trapProcess
 1.3.6.1.4.1.169.3.12.5
 not-accessible
 DisplayString (SIZE
 (1..50))
The process 
descriptor of the 
process reporting the 
event.
For a named process:
 node-
name.process-
 name.sequence-
number
For an unnamed 
process:
 node-name.
$:cpu:pin:sequence-
 number
node-name identifies 
the system on which the 
process resides.
process-name is the 
name assigned at startup 
time, of the form $name, 
where name has from 
one through five 
characters.
sequence-number is 
an integer used to 
distinguish among 
different instances of a 
process.
cpu:pin is a process 
ID consisting of a 
processor module 
number (cpu) and a 
processor identification 
number (pin).
ZEMS-TKN-PROC-
DESC token value.
trapGenerationtime
 1.3.6.1.4.1.169.3.12.6
 not-accessible
 DisplayString (SIZE 
19)
The time when the 
event was generated.
YYYY/MM/DD 
HH:MM:SS.
ZEMS-TKN-
GENTIME token 
value.
Table 9-1. Objects in the EMS Trap MIB  (page 3 of 4)
Object and Attributes Definition Format of Value Derivation of Value