SNMP Configuration and Management Manual

Trap Multiplexer Subagent/Manager
SNMP Configuration and Management Manual424777-006
12-20
ztmxProcess Group Maintenance
ztmxProcess Group Maintenance
The ztmxProcess group values are updated:
At Trap Multiplexer startup time. The values of MIB objects associated with startup
parameters and startup process attributes are initialized.
When traps and requests are received. The counters in the
ztmxPDUStatisticsGroup, the counters that tally the write operations to the EMS
collector, and the values of ztmxProcCpuTime and ztmxProcHeapCurrent are
updated as traps and requests are received.
When a request is received from an SNMP manager to change the Trap
Multiplexer’s process priority. The value of ztmxProcPri does not persist after the
Trap Multiplexer stops. The next time the Trap Multiplexer starts, this object is
assigned the priority specified at invocation.
ztmxProcEmsWriteTotal
1.3.6.1.4.1.169.3.185.2.20
read-only
Counter
The total number
of attempts to
write an event
message
converted from a
trap to the EMS
collector.
Integer without leading 0s. Trap Multiplexer.
ztmxProcEmsWriteErrors
1.3.6.1.4.1.169.3.185.2.21
read-only
Counter
The total number
of write
operations to the
EMS collector
that could not be
completed.
Integer without leading 0s. Trap Multiplexer.
ztmxProcKeepAliveTimer
1.3.6.1.4.1.169.3.185.2.22
read-write
INTEGER
The number of
seconds between
attempts the
subagent makes
to connect a
TCP/IP process.
Integer without leading 0s. The value specified in
the -k startup
parameter. If not
specified, the default
is 15 minutes.
After startup, the
value can be set from
an SNMP manager.
Table 12-3. ztmxProcess Group Objects Supported by Trap Multiplexers
MIB (page 4 of 4)
Object and Attributes Definition Format of Value Derivation of Value