SNMP Configuration and Management Manual

IPX/SPX Subagent (G-Series)
SNMP Configuration and Management Manual424777-006
13-71
1011: ZISA-EVT-MEMORY-ALLOC-FAILURE
ZISA-EVT-MEMORY-ALLOC-FAILURE
is the event number (1011). The DDL AS clause of this value (“memory-allocation-
failure”) appears in the message text following “event number:”.
ZISA-VAL-TF-MEM
characterizes the type of transient fault that occurred. The DDL AS clause of this
value ( “Memory-allocation”) is inserted in the message text following “fault type:”.
ZEMS-TKN-CONTENT-USER
is assigned the value “undefined” in the message text following “user content:”.
ZISA-TNM-MEM-ALLOC-SIZE
is the number of bytes the subagent tried to allocate.
Cause. The subagent could not allocate the memory needed to perform an operation.
The subagent allocates memory for various operations, including responding to SNMP
requests and adding a new entry to the tdmNwSaIPXPROTONamesTable, the
tdmNwSaAgentNamesTable, and the tdmNwServerTable.
Effect. The operation could not be completed.
Recovery. Stop the subagent if necessary; try using another disk as a swap device. If
the problem persists, contact your service provider and provide all relevant information
as follows:
Descriptions of the problem and accompanying symptoms
Details from the message or messages generated
Supporting documentation such as EMS logs
If your local operating procedures require contacting the GCSC, supply your system
number and the numbers and versions of all related products as well.
Sample Message
96-01-30 16:50:50 \COMM.$ZISA TANDEM.IPXSA.D30 001011 Transient Fault
IPX/SPX-SNMP-subagent-process - \COMM.$ZISA,
event number: memory-allocation-failure,
fault type: Memory-allocation, user content:
undefined