3006: ZESA-EVT-BACKUP-OBJ-UNAVAIL
ZEMS-VAL-NULL
indicates the type of subsystem defined event. Because the Ethernet Subagent
process has not defined this as a private event, the DDL AS clause “undefined”
always appears in the message text following “user content.”
Cause. The backup Ethernet Subagent process stopped or failed to start.
Effect. The Ethernet Subagent process continues to run without a backup.
Configuration changes are not saved if a primary process failure occurs.
Recovery. Check the status of the configured backup processor (zesaBackupCPU). If
it is not available or there are insufficient resources to run a backup process, disable
the backup (set zesaBackupState “Disabled (3)”), set the zesaBackupCPU to an
available processor, and reenable the backup (set zesaBackupState “Enabled(4)”).
Sample Message
98-07-08 30:54:34 \NOVA.$ZESA TANDEM.ETHSA.G06 003006
Object unavailable backup-process -
\NOVA.$ZESA:384566222,
event number: backup-process-unavailable,
cause: underlying-serv-failed,
previous state: connected,
current state: disconnected,
underlying object: \NOVA.$ZESA:384566222,
symptom string: T0326G06_25JUN98_ETHSA,
user content: undefined
98-07-08 11:12:19 \NOVA.$ZESA TANDEM.ETHSA.G06 003006
Object unavailable backup-process -
\NOVA.$ZESA:384566222,
event number: backup-process-unavailable,
cause: operator-initiated,
previous state: connected,
current state: disconnected,
user content: undefined