SNMP Configuration and Management Manual
SCF Error Messages for the NonStop Agent
SNMP Configuration and Management Manual—424777-006
B-6
SNMP Error 00007
SNMP Error 00007 
Cause. The NonStop agent could not update the SNMPCTL file with the configuration 
change you submitted.
Effect. The command is executed, but the SNMPCTL file no longer reflects the current 
environment.
Recovery. Check the event log to find out the corresponding file system error number. 
Then refer to the Guardian Procedure Errors and Messages Manual for a description of 
file system errors and possible recovery actions.
SNMP Error 00009 
Cause. You tried to define an invalid dotted-decimal format Internet address for the 
HOSTADDR attribute.
Effect. The ADD or ALTER command is not executed.
Recovery. Redefine the object and specify a valid Internet address. For information on 
specifying Internet addresses, see the TCP/IP Configuration and Management Manual. 
SNMP W00007 Unable to update SNMPCTL file.
SNMP E00009 Internet address invalid